Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Packaging | Series | ProductStatus | Applications | PressureType | OperatingPressure | OutputType | Output | Accuracy | Voltage-Supply | PortSize | PortStyle | Features | TerminationStyle | MaximumPressure | OperatingTemperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PPT0500GFR5VAPRESSURE TRANSDUCER |
936 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFR5VBPRESSURE TRANSDUCER |
2,792 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFW2VAPRESSURE TRANSDUCER |
3,754 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFW2VBPRESSURE TRANSDUCER |
2,994 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFW5VAPRESSURE TRANSDUCER |
3,108 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFW5VBPRESSURE TRANSDUCER |
2,559 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFX2VAPRESSURE TRANSDUCER |
2,872 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Female - 1/8 (3.18mm) Swagelok™, Filter | Filtered, Threaded | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFX2VBPRESSURE TRANSDUCER |
2,685 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Female - 1/8 (3.18mm) Swagelok™, Filter | Filtered, Threaded | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFX5VAPRESSURE TRANSDUCER |
808 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Female - 1/8 (3.18mm) Swagelok™, Filter | Filtered, Threaded | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GFX5VBPRESSURE TRANSDUCER |
2,187 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Female - 1/8 (3.18mm) Swagelok™, Filter | Filtered, Threaded | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRF2VAPRESSURE TRANSDUCER |
1,110 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRF2VBPRESSURE TRANSDUCER |
1,791 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRF5VAPRESSURE TRANSDUCER |
1,623 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRF5VBPRESSURE TRANSDUCER |
2,143 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Filter | Barbed, Filtered | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRR2VAPRESSURE TRANSDUCER |
1,846 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Dual | Barbed | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRR2VBPRESSURE TRANSDUCER |
2,202 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Dual | Barbed | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRR5VAPRESSURE TRANSDUCER |
1,471 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Dual | Barbed | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRR5VBPRESSURE TRANSDUCER |
3,551 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-485 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Dual | Barbed | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRW2VAPRESSURE TRANSDUCER |
2,543 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Dual | Barbed | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C | |
![]() |
PPT0500GRW2VBPRESSURE TRANSDUCER |
1,460 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Vented Gauge | 500PSI (3447.38kPa) | Analog, RS-232 | 0 V ~ 5 V | ±0.05% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube, Dual | Barbed | - | Connector | 600PSI (4136.85kPa) | -40°C ~ 85°C |
Tel