Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Packaging | Series | ProductStatus | Applications | PressureType | OperatingPressure | OutputType | Output | Accuracy | Voltage-Supply | PortSize | PortStyle | Features | TerminationStyle | MaximumPressure | OperatingTemperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
HPA100W2DABAROMETER |
3,460 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-232 | - | ±0.06% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA100W5DABAROMETER |
699 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-485 | - | ±0.06% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA100WTTABAROMETER |
2,714 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | TTL | - | ±0.06% | 6V ~ 26V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA100X2DABAROMETER |
673 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-232 | - | ±0.06% | 5.5V ~ 30V | Female - 1/8 (3.18mm) Swagelok™ | Threaded | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA100X5DABAROMETER |
1,422 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-485 | - | ±0.06% | 5.5V ~ 30V | Female - 1/8 (3.18mm) Swagelok™ | Threaded | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA100XTTABAROMETER |
1,092 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | TTL | - | ±0.06% | 6V ~ 26V | Female - 1/8 (3.18mm) Swagelok™ | Threaded | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200F2DABAROMETER |
14,830 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-232 | - | ±0.03% | 5.5V ~ 30V | Filter | Filtered | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200F5DABAROMETER |
10,053 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-485 | - | ±0.03% | 5.5V ~ 30V | Filter | Filtered | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200FTTABAROMETER |
10,774 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | TTL | - | ±0.03% | 6V ~ 26V | Filter | Filtered | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200R2DABAROMETER |
13,711 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-232 | - | ±0.03% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200R5DABAROMETER |
11,233 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-485 | - | ±0.03% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200RTTABAROMETER |
10,035 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | TTL | - | ±0.03% | 6V ~ 26V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200W2DABAROMETER |
11,477 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-232 | - | ±0.03% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200W5DABAROMETER |
12,281 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-485 | - | ±0.03% | 5.5V ~ 30V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200WTTABAROMETER |
11,972 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | TTL | - | ±0.03% | 6V ~ 26V | Male - 0.13 (3.18mm) Tube | Barbed | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200X2DABAROMETER |
13,019 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-232 | - | ±0.03% | 5.5V ~ 30V | Female - 1/8 (3.18mm) Swagelok™ | Threaded | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200X5DABAROMETER |
14,178 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | RS-485 | - | ±0.03% | 5.5V ~ 30V | Female - 1/8 (3.18mm) Swagelok™ | Threaded | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPA200XTTABAROMETER |
11,835 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Active | Industrial Automation | Absolute | 17.6PSI (121.35kPa) | TTL | - | ±0.03% | 6V ~ 26V | Female - 1/8 (3.18mm) Swagelok™ | Threaded | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPB100F2DABAROMETER |
3,997 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Absolute | 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) | RS-232 | - | ±0.012PSI (±0.08kPa) | 5.5V ~ 30V | Filter | Filtered | - | Connector | - | -40°C ~ 85°C | |
![]() |
HPB100F5DABAROMETER |
2,507 | 0.00 |
RFQ |
![]() Datasheet |
Bulk | - | Obsolete | Industrial Automation | Absolute | 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) | RS-485 | - | ±0.012PSI (±0.08kPa) | 5.5V ~ 30V | Filter | Filtered | - | Connector | - | -40°C ~ 85°C |